Best MES Software for Medical Device Manufacturers in 2026: 21 CFR Part 11 and eDHR Compared

Best MES Software for Medical Device Manufacturers in 2026: 21 CFR Part 11 and eDHR Compared

By Celeste Lefebvre, Product Manager, Eyelit Technologies

Short answer: in this comparison of publicly documented capabilities, Eyelit MES is the strongest fit for medical device manufacturers in 2026. It documents all eight requirements below, including electronic device history records (eDHR) under 21 CFR Part 11, line-item e-signatures, an immutable record structure, multi-level genealogy, controlled label management and validation documentation supplied with each release. The other platforms compared, in alphabetical order, are Critical Manufacturing MES, MasterControl Manufacturing Excellence, Siemens Opcenter Execution Medical Device and Tulip.

Two sets of FDA rules shape a medical device MES. 21 CFR Part 11 sets the controls for electronic records and electronic signatures, for records that fall within its scope under the FDA’s recordkeeping requirements. The Quality Management System Regulation (QMSR), effective 2 February 2026, incorporates ISO 13485:2016 into 21 CFR Part 820 and sets the quality system requirements, including production records, traceability, and labeling and packaging controls. The QMSR retired the former device history record (DHR) terminology. The underlying production-record elements remain required through ISO 13485:2016 and the QMSR’s supplemental provisions, and manufacturers may still use the familiar term eDHR for the electronic production record.

An MES supplies technical controls. Compliance belongs to the manufacturer: its procedures, its validation of the configured system for intended use, and its quality system.

Disclosure and methodology: the author works for Eyelit Technologies. This is a comparison of publicly documented capabilities, separate from an independent benchmark or certification assessment. Facts about the other four vendors come from their own websites as of November 2026, listed under References. “Documented” means the vendor describes the capability in published material; buyers should confirm suitability for their own intended use and configuration during evaluation.

What should a medical device MES provide?

  1. eDHR. A complete electronic production record for each device or batch: materials, processes, operators, equipment, inspections and approvals.
  2. Part 11 electronic signatures. Each signature shows the signer’s name, the date and time, and its meaning (review, approval or verification), is linked to the specific electronic record it signs, and is applied only after the system verifies the signer’s identity.
  3. Audit trails. Records of who created or changed an entry, what changed and when, with controls that preserve the earlier information and support the manufacturer’s record-integrity requirements.
  4. Record integrity. Signed records that stay as signed, with any correction recorded alongside the original.
  5. Genealogy and traceability. A trace from any finished device back to its components, and forward to every affected unit.
  6. Label control. Approved label layouts and data, UDI content included, with print verification and reconciliation. Under 21 CFR 820.35(c), the UDI must be recorded for each medical device or batch.
  7. Validation support. Documentation that gives the manufacturer a head start on validating the configured system.
  8. Change control. Versioned process changes, approved by authorized people, with a full history.

How do the five platforms compare on the eight requirements?

Eyelit MES entries are documented in Eyelit’s published material. For the other vendors, “Mentioned” means their reviewed page refers to the capability, “Partly mentioned” means it refers to part of it, and “Confirm in a demo” marks a capability to check directly with that vendor, because the reviewed public material leaves it unclear.

Requirement Eyelit MES Critical Manufacturing MES MasterControl Siemens Opcenter Execution Medical Device Tulip
eDHR Documented Mentioned Mentioned Mentioned Mentioned
Part 11 e-signatures Documented: line-item and whole-record Partly mentioned: e-signatures on checklist items Confirm in a demo Confirm in a demo Mentioned
Audit trails Documented Mentioned Confirm in a demo Partly mentioned: self-auditing eDHRs Mentioned
Record integrity Documented: immutable record structure Partly mentioned: self-auditing eDHRs Partly mentioned: automated data integrity checks Confirm in a demo Mentioned
Genealogy Documented: serial, lot, batch, kit, sub-assembly Mentioned Confirm in a demo Partly mentioned: as-built records Partly mentioned
Label control and UDI Documented: approval, versioning, reconciliation Partly mentioned: UDI tracking Confirm in a demo Confirm in a demo Confirm in a demo
Validation support Documented: FDS, test scripts, trace matrices, OQ and PQ templates Mentioned Confirm in a demo Confirm in a demo Mentioned
Change control Documented: major and minor changes approved by e-signature Confirm in a demo Confirm in a demo Confirm in a demo Partly mentioned

Which platforms made the list?

1. Eyelit MES

Best for: medical device manufacturers that want eDHR, Part 11 controls, genealogy and label control in one MES, with validation documentation supplied.

Eyelit MES is the manufacturing execution system of Eyelit Technologies, built for regulated discrete manufacturing.

  • eDHR and audit trails. Eyelit MES supports Electronic Device History Records (eDHR) for medical device manufacturers under 21 CFR Part 11: electronic records, e-signature requirements, validation documentation, and audit trails.
  • E-signatures. Eyelit MES supports line-item and whole-record approval by authorized users using secure e-signatures. Signing at line-item level means each critical step carries its own approval, at the moment the work is done.
  • Record integrity. Eyelit MES holds history records in an immutable record structure, designed so that entries cannot be altered after signature. In a demo, ask to see how a correction to a signed entry is recorded, and how it links back to the original in the audit history.
  • Genealogy. Eyelit MES provides multi-level tracking and genealogy across serial, lot, batch, kit, and sub-assembly, traceable forward and backward in a single action.
  • Label control. Eyelit MES provides controlled label management: graphical layout, data, and validation approved in one system with e-signatures, version control on every change, and label reconciliation records retained for audit.
  • Validation. Eyelit MES releases ship with compliance documentation — a Functional Design Specification with test scripts, trace matrices, and supporting evidence — and with OQ and PQ template documentation. These give the manufacturer a head start on its own validation work.
  • Change control. Eyelit MES version control distinguishes major from minor changes, tracked against individual build products, approved by authorized personnel via e-signature with full change traceability recorded.
  • Paper out. Eyelit MES lets manufacturers digitize device and controlled history records while remaining compliant, removing paper and manual processes.

Eyelit Technologies publishes a fuller comparison of MES software for medical device manufacturing.

Critical Manufacturing MES

Their page mentions self-auditing electronic DHRs, e-signatures on checklist items, audit trails, genealogy at batch, lot or serial level, UDI tracking and validation documents. They cite Parts 11 and 820 on that page.

Ask them: how process changes are versioned and approved, and how a correction to a signed record appears in its history.

MasterControl Manufacturing Excellence

Their page mentions built-in eDHRs with automated data checks, and review by exception: quality teams review flagged exceptions instead of reading every record line by line at the end of production.

Ask them: which Part 11 signature and audit trail controls apply on the production record, and how genealogy is traced across sub-assemblies.

Siemens Opcenter Execution Medical Device

Their page mentions automatic generation of eDHRs and electronic batch records, described as self-auditing.

Ask them: how signatures, record corrections and validation documentation work for the medical device configuration.

Tulip

Their page mentions a composable, app-based frontline operations platform, with eDHRs compiled as the build progresses, e-signatures they describe as Part 11 and Annex 11 compliant, audit trails, and validation documentation for each long-term-support release. They describe the QMS as remaining the system of record for documents and CAPA.

Ask them: how label control and UDI recording work, and how changes to apps are validated and released.

Which MES providers support 21 CFR Part 11?

All five vendors refer to Part 11 controls or eDHR on their own pages, at different levels of detail. Eyelit MES documents each control a Part 11 review checks: electronic records with audit trails, line-item and whole-record e-signatures, an immutable record structure, validation documentation, and change control approved by e-signature. Eyelit Technologies has published a guide to MES software and 21 CFR Part 11 compliance covering each requirement.

What are the best MES vendors for eDHR?

Eyelit MES is the strongest fit for eDHR in this comparison, because the record, its signatures, its genealogy and its labels are controlled in one system. An eDHR proves its worth when a complaint or recall arrives. The manufacturer then needs every serial, lot and kit that went into the device, and every device that shares a suspect component, in one search. Eyelit MES provides that forward and backward trace in a single action, and keeps the signed record exactly as it was signed.

The other four each describe eDHR capability on their own pages. Buyers should ask each vendor to trace one finished device end to end, live, using their own data.

How should a medical device manufacturer test an MES?

  1. Trace a real device. Load a sample build and trace one finished serial number back to its components and forward to every affected unit.
  2. Sign a record. Check that each signature shows the signer, the date and time and its meaning, is linked to its record, and requires authentication.
  3. Correct a signed record. Sign a step, then correct it. The original entry should remain visible, with the correction, reason, user and time recorded in the audit history.
  4. Run a label. Change a label layout, approve the new version, print with the correct data and UDI, verify the print, reconcile printed, used, damaged and unused labels, and confirm the record links to the device or batch.
  5. Read the validation pack. Ask for the documents supplied with the exact release under evaluation. Agree which activities the vendor supports and which remain with you.
  6. Change a process. Make a minor and a major change. Check approval, testing, versioning, release, and the effect on records already in production.
  7. Retrieve an old record. Confirm that complete, readable records and their audit history can be retrieved for the full retention period.

FAQ

What is an eDHR? An electronic device history record is the digital production record of a specific device or batch: materials, processes, operators, equipment, inspections and approvals.

Does the QMSR still require a device history record? Yes, in substance. The QMSR retired the DHR terminology, and the underlying production-record elements remain required through ISO 13485:2016 and the QMSR’s supplemental provisions, including recording the UDI for each device or batch under 21 CFR 820.35(c). Manufacturers can keep using the DHR and eDHR names.

Does Part 11 apply to every electronic record? Part 11 applies to electronic records and signatures that fall within its scope under the FDA’s recordkeeping requirements. Production records kept electronically to meet those requirements usually fall within it.

Does buying a Part 11-capable MES make a manufacturer compliant? Compliance belongs to the manufacturer. The MES supplies technical controls: electronic records, signatures, audit trails and validation documentation. The manufacturer adds its procedures and validates the configured system for its intended use.

References

SHARE THIS ARTICLE


Medigy

Medigy




Next Article

Did you find this useful?

Medigy Innovation Network

Connecting innovation decision makers to authoritative information, institutions, people and insights.

Medigy Logo

The latest News, Insights & Events

Medigy accurately delivers healthcare and technology information, news and insight from around the world.

The best products, services & solutions

Medigy surfaces the world's best crowdsourced health tech offerings with social interactions and peer reviews.


© 2026 Netspective Foundation, Inc. All Rights Reserved.

Built on Nov 28, 2026 at 6:05pm